P9241A

Request for Availability

Keysight/Agilent P9241A, 2 Analog Channels, 6-in-1 Instrumentation, 200 MHz Bandwidth, Streamline USB Oscilloscope

Rated 5/5  |  19 ratings

❮ ❯

Actual item may vary if no part number is provided on quote request.

Keysight Agilent HP - Keysight Oscilloscopes - P9241A
Keysight Agilent HP - Keysight Oscilloscopes - P9241A - Wiring
P9241A New
P9241A Refurbished

✔ 2 Year Warranty Included

✔ Free Domestic Ground Shipping

✔ NIST Calibration Available

Request a Quote

Get Price & Availability for the P9241A

Fast response from an Apex Waves specialist.

Fast Response Avg. 15 min
ISO 9001 Quality 2 Year Warranty
Check Availability Get Current Lead Time

Keysight/Agilent P9241A Streamline Series USB Oscilloscope

The Keysight P9241A is a two-channel USB oscilloscope from the Streamline Series product line. It delivers a -3 dB analog bandwidth of 200 MHz for industrial automation signal testing. It achieves a calculated rise time of 1.75 ns measured from the 10 to 90 percent signal threshold. It connects via USB and integrates directly into PC-based test environments for portable and bench use. The maximum sample rate of the oscilloscope is 5 GSa/s when operating on a single active channel. With both channels active simultaneously, the sample rate reduces to 2.5 GSa/s per channel. The standard memory depth is 4 Mpts, and the instrument includes segmented memory as a standard configuration. The waveform update rate exceeds one million waveforms per second, enabling capture of high-speed transient signal events.

The vertical system of the P9241 A USB oscilloscope includes selectable hardware bandwidth limiting at approximately 20 MHz. The input coupling is available in both AC and DC modes for flexible signal acquisition. The input impedance is user-selectable between 1 MΩ ± 1 % at 15 pF and 50 Ω ± 3 % tolerance. The input sensitivity ranges from 1 mV per division to 5 V per division across both impedance settings. The vertical resolution is 8 bits and improves to 12 bits of measurement resolution through signal averaging. The maximum rated direct input voltage is 135 Vrms for standard measurement configurations. The included N2843A 10:1 passive probe extends the safe measurement range up to 300 Vrms. The DC vertical gain accuracy is ± ±2.0% full scale, and DC vertical offset accuracy is ±0.1 div ±2 mV ±1% of the offset setting.

The vertical offset range of the Keysight P9241A USB oscilloscope is ± 2 V for sensitivity settings from 1 mV per division to 200 mV per division. For settings above 200 mV per division, the offset range extends to a maximum of ± 50 V. The channel-to-channel skew exceeds 100:1 from DC to the maximum specified bandwidth of the instrument. The channel-to-channel deskew range is ± 100 ns for precise multi-channel signal timing alignment.

P9241A Technical Specifications
ModelP9241A
ManufacturerKeysight/Agilent
Part TypeStreamline Series P9241A USB Oscilloscope
Hardware Bandwidth LimitsApproximately 20 MHz
Input couplingAC, DC
Input Impedance1 MΩ Or 50 Ω
Input Sensitivity Range1 mV/div To 5 V/div
Vertical Resolution8 Bits
Maximum Input Voltage135 Vrms

Associated part numbers for P9241A:

Delivery:

Free FedEx or UPS Ground shipping is offered on domestic orders. Expedited and international options are available; shipping other than domestic ground is customer-paid.

View shipping and delivery policy

All of our products are covered by our Apex Waves Warranty.

✓ 3 Year Warranty - New Surplus Parts

✓ 2 Year Warranty - Refurb / Fully Tested Parts

Eligible returns may be accepted within 30 days at Apex Waves’ discretion. A 25% restocking fee applies; non-refundable and built-to-order products are excluded.

View returns policy or submit a return request.

Payment:

Authorize.net Visa Master Card American Express Truist icon logo Better Business Bureau Dun & Bradstreet

Receive Price & Availability Today!

Ask About Our Tiered Calibration Levels

Option & Modules:

Confirm Your Requirements or Versions

Cost & Lead Time Available Upon Request for Service

Repair Evaluation: $150

Share this page:

Common Typos:

PI241A, PO241A, PP241A, P9241Q, P9241Z

Why Buy From Apex Waves:

Video thumbnail for Apex Waves Unboxing Experience Video