E1332A

Request for Availability

Keysight/Agilent E1332A, 1 Slot, 7 Counter Functions, Programmable Inputs, VXI 4-Channel Counter/Totalizer

Rated 4.5/5  |  19 ratings

❮ ❯

Actual item may vary if no part number is provided on quote request.

E1332A Keysight VXI 4-Channel Counter | Request a Quote | Image
E1332A Keysight VXI 4-Channel Counter | Request a Quote | Image
E1332A New
E1332A Refurbished

✔ 2 Year Warranty Included

✔ Free Domestic Ground Shipping

✔ NIST Calibration Available

Request a Quote

Get Price & Availability for the E1332A

Fast response from an Apex Waves specialist.

Fast Response Avg. 15 min
ISO 9001 Quality 2 Year Warranty
Check Availability Get Current Lead Time

Keysight/Agilent E1332A 4-Channel Counter/Totalizer

The E1332A 4 Channel Counter Totalizer delivers advanced register-based measurements within VXI environments. The unit supports 7 programmable counter functions for industrial testing applications. The B-size single-slot module processes frequency measurements reaching accurate operating ranges up to 4 megahertz. It performs precise period averaging during complex timing verification procedures.

The integrated architecture supports pulse width analysis for repetitive electronic signals requiring stable acquisition performance consistently. Time interval functionality enables synchronized event monitoring during automated validation sequences across connected instrumentation platforms effectively.

The gated totalize capabilities support reliable accumulation processes during continuous production monitoring operations without interruption. The E1332A Counter module also performs up-down counting functions for advanced directional event tracking within measurement systems. The unit provides programmable direct inputs supporting flexible signal acquisition across multiple operating environments. The software-controlled isolated inputs improve measurement reliability. Users can multiplex 8 available channels through four isolated paths and four direct non-isolated acquisition connections.

The digital input filter provides selectable low-pass frequencies through 16 binary configurable operating ranges independently. The selectable filtering frequencies extend from 4 hertz through 131 kilohertz during measurement conditioning operations. The totalizer maintains accurate threshold responses through programmable trigger level configuration features. Input high voltage levels remain above 4.2 volts during stable measurement recognition procedures consistently maintained.
The input low voltage thresholds remain below 1 volt, ensuring dependable digital state detection throughout operational measurement sequences. High current input requirements exceed 16.3 milliamperes, supporting controlled signal validation. The low current thresholds were found to be below 250 microamperes for efficient low-level input recognition during operation. The module supports gated event accumulation across paired channels during synchronized counting procedures effectively.

The channel-2 controls gating functions affecting channel one during configurable totalized event monitoring operations under software management. Channel 4 independently controls channel 3 during paired gated counting sequences, requiring selectable operational polarity configurations accurately. This enables counting operations whenever corresponding control channels maintain programmed high or low conditions continuously.

The E1332A supports dependable frequency measurements beginning at extremely low operating ranges near 0.002 hertz. The compact single-slot construction conserves valuable chassis space within densely integrated VXI testing installations during deployment. The maximum readable values reach 64K counts through integrated 16-bit counting architecture during operation sequences. The oftware commands configure isolated selections directly without requiring manual hardware modifications during operational measurement adjustments frequently.

E1332A Technical Specifications
ModelE1332A
ManufacturerKeysight/Agilent
Part Type4-Channel Counter/Totalizer
Measurement Frequency Range0.002 Hz to 4 MHz
Maximum Frequency4 MHz
Input ConfigurationProgrammable Direct or Isolated Inputs
Filter Frequency Range4 Hz to 131 kHz
High Voltage ThresholdGreater than 4.2 V
Low Voltage ThresholdLess than 1 V
Maximum Count64K Counts with 16-Bit Architecture

Associated part numbers for E1332A:

Delivery:

Free FedEx or UPS Ground shipping is offered on domestic orders. Expedited and international options are available; shipping other than domestic ground is customer-paid.

View shipping and delivery policy

All of our products are covered by our Apex Waves Warranty.

✓ 3 Year Warranty - New Surplus Parts

✓ 2 Year Warranty - Refurb / Fully Tested Parts

Eligible returns may be accepted within 30 days at Apex Waves’ discretion. A 25% restocking fee applies; non-refundable and built-to-order products are excluded.

View returns policy or submit a return request.

Payment:

Authorize.net Visa Master Card American Express Truist icon logo Better Business Bureau Dun & Bradstreet

Receive Price & Availability Today!

Ask About Our Tiered Calibration Levels

Option & Modules:

Confirm Your Requirements or Versions

Cost & Lead Time Available Upon Request for Service

Repair Evaluation: $150

Share this page:

Common Typos:

W1332A, E13W2A, E13E2A, E133WA, E1332Q

Why Buy From Apex Waves:

Video thumbnail for Apex Waves Unboxing Experience Video