Anonymous Verified Buyer
" Very responsive and helpful, competitive pricing. Good source! "
July 2025
NI-9862, 9-Pin Male DSUB Connector, 1 Port, High Speed NI CAN Interface Module
Actual item may vary if no part number is provided on quote request.
✔ 2 Year Warranty Included
✔ Free Domestic Ground Shipping
✔ NIST Calibration Available
Expert Insights for the NI-9862
"The NI-9862 is a high-speed CAN interface that uses the NI-XNET driver. It is perfect for real-time, high-speed CAN projects that need rapid bus monitoring and automated controlling. This device can change and take measurements at the same time, making it a great choice for low-level FPGA programming. This device is compatible with either CompactDAQ and CompactRIO systems, but FPGA programming is only available with CompactRIO chassis."
- Chris B.
LabVIEW Trained
In-House Technician
Expert Insights for the NI-9862
"The NI-9862 is a high-speed CAN interface that uses the NI-XNET driver. It is perfect for real-time, high-speed CAN projects that need rapid bus monitoring and automated controlling. This device can change and take measurements at the same time, making it a great choice for low-level FPGA programming. This device is compatible with either CompactDAQ and CompactRIO systems, but FPGA programming is only available with CompactRIO chassis."
- Chris B.
LabVIEW Trained
In-House Technician
National Instruments NI-9862 C Series CAN Interface Module
The NI-9862 (Part number(s): 781639-01) C Series CAN FD Interface has a high-speed interface to quickly transfer data and signals from frame to signal in various applications such as RCP, HIL-Simulation, Bus Monitoring, Automated Control, etc. The module uses an NI-XNET driver to allow integration with other systems. The isolated CAN port includes a Bosch DCAN controller and an NXP TJA1041AT transceiver. The product complies with all specifications of CAN 2.0 B, which includes 11-bit or 29-bit identifiers and a max baud rate of 1 Mbit/s. The NI-9862 weighs about 144 grams. It will consume up to 1 watt when running. Under load conditions, the device produces a thermal output of 1.25 watts at 70°C.
For proper operation of the CAN port, an external power source of +9VDC to +30VDC is required on the VSUP for CAN ports. Pin #2 of the 9-pin male D-sub connector connects directly to the CAN_L pin, while pins #3 & #6 connect directly to the COM pin, pin #5 is the shield connection, pin #7 connects directly to the CAN_H pin, and pin #9 is the VSUP connection. A software-selectable termination resistor of 120Ω nominal value is connected across the CAN_H and CAN_L pins. While this termination resistor is recommended as part of the documentation for this Interface Module, it should be noted that acceptable values for the termination resistor have been provided as 100Ω to 130Ω.
The ingress protection rating is IP40. Non-condensing relative humidity during operation ranges from 10% to 90%. During storage conditions, non-condensing relative humidity ranges from 5% to 95%. Port-to-earth isolation ratings are 60VDC continuous, Measurement Category I, and can withstand 500 VRMS for 5 seconds. According to NI, users should avoid connecting signals to or using the device for measurement purposes in CAT II, CAT III, CAT IV, or MAINS circuits. The NI-9862 has been tested for both random and sinusoidal operating vibrations (5g RMS and 5g from 10Hz through 500Hz), and operating shocks (30g/11ms and 50g/3ms half-sine). This module may be used in both Compact RIO systems for embedded monitoring and low-level FPGA control, as well as in Compact DAQ systems for parallel data acquisition.
| Model | NI-9862 |
|---|---|
| Manufacturer | National Instruments |
| Part Number | 781639-01 |
| Type | C Series CAN Interface Module |
| Ports | 1 |
| CAN Physical Layer | Flexible Data-Rate, High-Speed |
| Maximum Baud Rate | 1 Mbps |
| Transceiver | NXP TJA1041AT |
| Power Consumption from Chassis | 1 W Maximum |
| Thermal Dissipation | 1.25 W Maximum. |
| Operating Temperature | -40 °C to 70 °C |
| Storage Temperature | -40 °C to 85 °C |
| Weight | 5.0 oz. |
| CAN Support | CAN FD high-speed; Bosch DCAN; CAN 2.0B; 11/29-bit IDs |
| NI-9862 Manual | 9-pin male D-Sub; software-selectable 120 Ω |
| Connector Termination | Software-selectable 120 Ω nominal; 100–130 Ω acceptable |
| Ingress Protection | IP40 |
| Bus Termination | Software-selectable 120 Ω nominal; 100–130 Ω acceptable |
| Humidity | Operating 10–90% RH, Storage 5–95% RH, noncondensing |
| Vibration | Random 5 g RMS, 10–500 Hz; sinusoidal 5 g, 10–500 Hz |
| Price | User Manual and Maintenance Manual Available for Download |
| Isolation | 60 V DC continuous, CAT I; 500 V RMS withstand, 5 s (Port-to-Earth) |
Associated part numbers for NI-9862:
National Instruments NI-9862 Frequently Asked Questions
Question: Which type of transceiver does the NI-9862 have?
Answer: The CAN Interface Module has a NXP TJA1041AT transceiver.
Question: What is the maximum port-to-COM voltage?
Answer: The maximum port-to-COM voltage for the NI-9862 is -27 to +40 VDC max, Measurement Category I.
Question: What driver software is used with the NI-9862?
Answer: The driver software used with the Interface Module is NI-XNET.
Question: Which type of bus termination does the module have?
Answer: The NI-9862 has software-selectable bus termination.
Delivery:
Eligible returns may be accepted within 30 days at Apex Waves’ discretion. A 25% restocking fee applies; non-refundable and built-to-order products are excluded.
Receive Price & Availability Today!
Ask About Our Tiered Calibration Levels
Option & Modules:
Confirm Your Requirements or Versions
Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Common Typos: