NI-9862

In Stock | Ships Today

NI-9862, 9-Pin Male DSUB Connector, 1 Port, High Speed NI CAN Interface Module

Rated 4.9/5  |  10 ratings

❮ ❯

Actual item may vary if no part number is provided on quote request.

NI-9862 National Instruments CAN Interface Module | Apex Waves | Image
NI-9862 National Instruments CAN Interface Module | Apex Waves | Image
NI-9862 New
NI-9862 Refurbished

✔ 2 Year Warranty Included

✔ Free Domestic Ground Shipping

✔ NIST Calibration Available

Expert Insights for the NI-9862

"The NI-9862 is a high-speed CAN interface that uses the NI-XNET driver. It is perfect for real-time, high-speed CAN projects that need rapid bus monitoring and automated controlling. This device can change and take measurements at the same time, making it a great choice for low-level FPGA programming. This device is compatible with either CompactDAQ and CompactRIO systems, but FPGA programming is only available with CompactRIO chassis."

technician's profile picture

- Chris B.

LabVIEW Trained

In-House Technician

Request a Quote

Get Price & Availability for the NI-9862

Fast response from an Apex Waves specialist.

Fast Response Avg. 15 min
ISO 9001 Quality 2 Year Warranty
In Stock Ships Today

Expert Insights for the NI-9862

"The NI-9862 is a high-speed CAN interface that uses the NI-XNET driver. It is perfect for real-time, high-speed CAN projects that need rapid bus monitoring and automated controlling. This device can change and take measurements at the same time, making it a great choice for low-level FPGA programming. This device is compatible with either CompactDAQ and CompactRIO systems, but FPGA programming is only available with CompactRIO chassis."

technician's profile picture

- Chris B.

LabVIEW Trained

In-House Technician

National Instruments NI-9862 C Series CAN Interface Module

The NI-9862 (Part number(s): 781639-01) C Series CAN FD Interface has a high-speed interface to quickly transfer data and signals from frame to signal in various applications such as RCP, HIL-Simulation, Bus Monitoring, Automated Control, etc. The module uses an NI-XNET driver to allow integration with other systems. The isolated CAN port includes a Bosch DCAN controller and an NXP TJA1041AT transceiver. The product complies with all specifications of CAN 2.0 B, which includes 11-bit or 29-bit identifiers and a max baud rate of 1 Mbit/s. The NI-9862 weighs about 144 grams. It will consume up to 1 watt when running. Under load conditions, the device produces a thermal output of 1.25 watts at 70°C.

For proper operation of the CAN port, an external power source of +9VDC to +30VDC is required on the VSUP for CAN ports. Pin #2 of the 9-pin male D-sub connector connects directly to the CAN_L pin, while pins #3 & #6 connect directly to the COM pin, pin #5 is the shield connection, pin #7 connects directly to the CAN_H pin, and pin #9 is the VSUP connection. A software-selectable termination resistor of 120Ω nominal value is connected across the CAN_H and CAN_L pins. While this termination resistor is recommended as part of the documentation for this Interface Module, it should be noted that acceptable values for the termination resistor have been provided as 100Ω to 130Ω.

The ingress protection rating is IP40. Non-condensing relative humidity during operation ranges from 10% to 90%. During storage conditions, non-condensing relative humidity ranges from 5% to 95%. Port-to-earth isolation ratings are 60VDC continuous, Measurement Category I, and can withstand 500 VRMS for 5 seconds. According to NI, users should avoid connecting signals to or using the device for measurement purposes in CAT II, CAT III, CAT IV, or MAINS circuits. The NI-9862 has been tested for both random and sinusoidal operating vibrations (5g RMS and 5g from 10Hz through 500Hz), and operating shocks (30g/11ms and 50g/3ms half-sine). This module may be used in both Compact RIO systems for embedded monitoring and low-level FPGA control, as well as in Compact DAQ systems for parallel data acquisition. 

NI-9862 Technical Specifications
ModelNI-9862
ManufacturerNational Instruments
Part Number781639-01
TypeC Series CAN Interface Module
Ports1
CAN Physical LayerFlexible Data-Rate, High-Speed
Maximum Baud Rate1 Mbps
TransceiverNXP TJA1041AT
Power Consumption from Chassis1 W Maximum
Thermal Dissipation1.25 W Maximum.
Operating Temperature-40 °C to 70 °C
Storage Temperature-40 °C to 85 °C
Weight5.0 oz.
CAN SupportCAN FD high-speed; Bosch DCAN; CAN 2.0B; 11/29-bit IDs
NI-9862 Manual9-pin male D-Sub; software-selectable 120 Ω
Connector TerminationSoftware-selectable 120 Ω nominal; 100–130 Ω acceptable
Ingress ProtectionIP40
Bus TerminationSoftware-selectable 120 Ω nominal; 100–130 Ω acceptable
HumidityOperating 10–90% RH, Storage 5–95% RH, noncondensing
VibrationRandom 5 g RMS, 10–500 Hz; sinusoidal 5 g, 10–500 Hz
PriceUser Manual and Maintenance Manual Available for Download
Isolation60 V DC continuous, CAT I; 500 V RMS withstand, 5 s (Port-to-Earth)

Associated part numbers for NI-9862:

National Instruments NI-9862 Frequently Asked Questions

 

Question: Which type of transceiver does the NI-9862 have?

Answer: The CAN Interface Module has a NXP TJA1041AT transceiver.

 

Question: What is the maximum port-to-COM voltage?

Answer: The maximum port-to-COM voltage for the NI-9862 is -27 to +40 VDC max, Measurement Category I.

 

Question: What driver software is used with the NI-9862?

Answer: The driver software used with the Interface Module is NI-XNET.

 

Question: Which type of bus termination does the module have?

Answer: The NI-9862 has software-selectable bus termination.

Delivery:

Free UPS Ground shipping is offered on domestic orders. Expedited and international options are available; shipping other than domestic ground is customer-paid.

View shipping and delivery policy

All of our products are covered by our Apex Waves Warranty.

✓ 3 Year Warranty - New Surplus Parts

✓ 2 Year Warranty - Refurb / Fully Tested Parts

Eligible returns may be accepted within 30 days at Apex Waves’ discretion. A 25% restocking fee applies; non-refundable and built-to-order products are excluded.

View returns policy or submit a return request.

Payment:

Authorize.net Visa Master Card American Express Truist icon logo Better Business Bureau Dun & Bradstreet

Receive Price & Availability Today!

Ask About Our Tiered Calibration Levels

Option & Modules:

Confirm Your Requirements or Versions

Cost & Lead Time Available Upon Request for Service

Repair Evaluation: $150

Share this page:

Common Typos:

NK-9862, NI-P862, NI-9O62, NI-98Y2, NI-98U2

Why Buy From Apex Waves:

Video thumbnail for Apex Waves Unboxing Experience Video