FD-11613 National Instruments Temperature Input Device for FieldDAQ | Apex Waves | ImageFD-11613 National Instruments Temperature Input Device for FieldDAQ | Apex Waves | ImageFD-11613 NewFD-11613 | Legacy, Refurbished and New Surplus
FD-11613 National Instruments Temperature Input Device for FieldDAQ | Apex Waves | Image
FD-11613 National Instruments Temperature Input Device for FieldDAQ | Apex Waves | Image
FD-11613 New
FD-11613 | Legacy, Refurbished and New Surplus

FD-11613

4.7/5 | 18 ratings

Modular Systems > National Instruments > FieldDAQ

Part Number FD-11613
Manufacturer/Brand National Instruments
Description: FD-11613, 8 Thermocouple Channels, Temperature Input Device for FieldDAQ
Request for Availablility
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments FD-11613 Temperature Input Device for FieldDAQ    

The FD-11613 is a Temperature Input Device. The NI FD-11613 device is created by National Instruments. The part number for the Temperature Input Device is 785640-01. The FD-11613 is operated and programmed with the NI-DAQmx driver software. The NI FD-11613 is installed on Windows operating systems. The FD-11613 comes with thermocouple channels for enabling temperature inputs. The NI FD-11613 Temperature Input Device is designed for cold junction compensating.

The National Instruments FD-11613 Temperature Input Device is manufactured for the FieldDAQ platform. The FD-11613 device comes with a maximum of 8 thermocouple channels. The NI FD-11613 is featured with open thermocouple detection. The module of an LED is offered at each channel of the FD-11613 device that identifies disconnected thermocouples. The NI FD-11613 Temperature Input Device is available with dust and water resistance capabilities, since it is rated with an ingress protection of IP67. The major advantage of the FD-11613 device is that it can bear the shock up to 100 g. The vibration of 10 g is supported by the NI FD-11613.

The NI FD-11613 Temperature Input Device is delivered with Time-Sensitive Networking functionality. The FD-11613 is incorporated with a network switch that is used for controlling the network connections. The National Instruments FD-11613 Temperature Input Device can perform simple daisy-chaining based on the internal architecture power circuitry. The NI FD-11613 is used within a temperature range of -40 to 85 °C for device operations. The FD-11613 can easily be synchronized with various FieldDAQ devices.

ModelFD-11613
ManufacturerNational Instruments
Part Number785640-01
TypeTemperature Input Device for FieldDAQ
Channels8 isolated thermocouple channels, 2 CJC
ADC Resolution24 bits
Type of ADCDelta-Sigma
Voltage Input Range9 V DC to 30 V DC
Maximum Device Power Consumption4.9 W
Dimensions7.8 in. × 3.0 in. × 1.9 in.
Weight40 oz.
Warranty2-3 Year Warranty
FD-11613 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for the FD-11613:

143886A-01L, 143886B-01L, 143886C-01L, 143886D-01L, 143886E-01L, 144843A-01L, 144843B-01L, 144843C-01L, 144948A-01L, 144948B-01L, 144948C-01L, 145229A-01L, 145229B-01L, 785640-01

  FD-11613 PDF Manuals

Driver Downloads for FD-11613






OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: FF-11613, FD-11T13, FD-116Q3, FD-1161E, FD-1161R

FD-11613



Modular Systems > National Instruments > FieldDAQ

FD-11613
4.7/5 | 18 ratings

FD-11613, 8 Thermocouple Channels, Temperature Input Device for FieldDAQ

Request for Availablility
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments FD-11613 Temperature Input Device for FieldDAQ    

The FD-11613 is a Temperature Input Device. The NI FD-11613 device is created by National Instruments. The part number for the Temperature Input Device is 785640-01. The FD-11613 is operated and programmed with the NI-DAQmx driver software. The NI FD-11613 is installed on Windows operating systems. The FD-11613 comes with thermocouple channels for enabling temperature inputs. The NI FD-11613 Temperature Input Device is designed for cold junction compensating.

The National Instruments FD-11613 Temperature Input Device is manufactured for the FieldDAQ platform. The FD-11613 device comes with a maximum of 8 thermocouple channels. The NI FD-11613 is featured with open thermocouple detection. The module of an LED is offered at each channel of the FD-11613 device that identifies disconnected thermocouples. The NI FD-11613 Temperature Input Device is available with dust and water resistance capabilities, since it is rated with an ingress protection of IP67. The major advantage of the FD-11613 device is that it can bear the shock up to 100 g. The vibration of 10 g is supported by the NI FD-11613.

The NI FD-11613 Temperature Input Device is delivered with Time-Sensitive Networking functionality. The FD-11613 is incorporated with a network switch that is used for controlling the network connections. The National Instruments FD-11613 Temperature Input Device can perform simple daisy-chaining based on the internal architecture power circuitry. The NI FD-11613 is used within a temperature range of -40 to 85 °C for device operations. The FD-11613 can easily be synchronized with various FieldDAQ devices.

ModelFD-11613
ManufacturerNational Instruments
Part Number785640-01
TypeTemperature Input Device for FieldDAQ
Channels8 isolated thermocouple channels, 2 CJC
ADC Resolution24 bits
Type of ADCDelta-Sigma
Voltage Input Range9 V DC to 30 V DC
Maximum Device Power Consumption4.9 W
Dimensions7.8 in. × 3.0 in. × 1.9 in.
Weight40 oz.
Warranty2-3 Year Warranty
FD-11613 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Software & Drivers





OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn