National Instruments - PXI Source Measure Units - PXIe-4147National Instruments - PXI Source Measure Units - PXIe-4147 - WiringPXIe-4147 NewPXIe-4147 | Legacy, Refurbished and New Surplus
National Instruments - PXI Source Measure Units - PXIe-4147
National Instruments - PXI Source Measure Units - PXIe-4147 - Wiring
PXIe-4147 New
PXIe-4147 | Legacy, Refurbished and New Surplus

PXIe-4147

5/5 | 20 ratings

Modular Systems > National Instruments > PXI Source Measure Units

Part Number PXIe-4147
Manufacturer/Brand National Instruments
Description: PXIe-4147, 40 W, 4 Channel, PXI Source Measure Unit
Request for Availablility
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PXIe-4147 Source Measure Unit

The PXIe-4147 (Part number: 786888-01) is a Source Measure Unit from National Instruments. Designed specifically for applications with high pin counts, the 4 channels of this device are each equipped with remote four-wire sensing capabilities, allowing for incredibly precise current and voltage readings. The features of the PXIe-4147 are made to improve flexibility and shorten test times- both important considerations when working with source and measurement applications. Boasting a nominal sample rate of (1.8 MS/s)/N, this device shortens the duration of measurements and offers a high resolution performance for projects of all sizes.

Switches, high-speed digital test modules, and other instruments can be easily synchronized to the PXIe-4147 by using a high-speed sequencing engine. NI’s SourceAdapt technology is another valuable addition to SMU toolkit. Built to use a digital control loop rather than an analog control loop, SourceAdapt optimizes the reaction of the PXIe-4147 to any load with minimal transients and maximum stability.

The sinking capacity of the PXIe-4147 is determined by the slot cooling capacity of the chassis. A chassis with a slot cooling capacity of ≥58 W will have a total sinking capacity of 40 W, while a chassis with a slot cooling capacity of <58 W provides a total of 15 W.

When in operation, the PXIe-4147 should be kept in temperatures ranging from 0 °C to 55 °C. When not in use, it can be safely kept in a temperature range spanning from -40 °C to 71 °C. The device weighs 448 g (15.8 oz) with 20 W and 428 g (15.1 oz) with 40 W. It measures dimensions of 2.0 cm × 13.0 cm × 21.6 cm (0.8 in. × 5.1 in. × 8.5 in.).

Model NamePXIe-4147
Part Number786888-01
Part TypePXI Source Measure Unit
Available Sample Rates(1.8 MS/s)/N
Input Trigger TypesStart, Source, Sequence Advance, Measure
# Channels4
Operating Temp Range0 °C to 55 °C
Dimensions2.0 cm × 13.0 cm × 21.6 cm (0.8 in. × 5.1 in. × 8.5 in.)
Weight448 g (15.8 oz)- 20 W,  428 g (15.1 oz)- 40 W
WarrantyThree Year Warranty
ManufacturerNational Instruments

  PXIe-4147 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: PXUE-4147, PXID-4147, PXIE-R147, PXIE-4W47, PXIE-41E7

PXIe-4147



Modular Systems > National Instruments > PXI Source Measure Units

PXIe-4147
5/5 | 20 ratings

PXIe-4147, 40 W, 4 Channel, PXI Source Measure Unit

Request for Availablility
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PXIe-4147 Source Measure Unit

The PXIe-4147 (Part number: 786888-01) is a Source Measure Unit from National Instruments. Designed specifically for applications with high pin counts, the 4 channels of this device are each equipped with remote four-wire sensing capabilities, allowing for incredibly precise current and voltage readings. The features of the PXIe-4147 are made to improve flexibility and shorten test times- both important considerations when working with source and measurement applications. Boasting a nominal sample rate of (1.8 MS/s)/N, this device shortens the duration of measurements and offers a high resolution performance for projects of all sizes.

Switches, high-speed digital test modules, and other instruments can be easily synchronized to the PXIe-4147 by using a high-speed sequencing engine. NI’s SourceAdapt technology is another valuable addition to SMU toolkit. Built to use a digital control loop rather than an analog control loop, SourceAdapt optimizes the reaction of the PXIe-4147 to any load with minimal transients and maximum stability.

The sinking capacity of the PXIe-4147 is determined by the slot cooling capacity of the chassis. A chassis with a slot cooling capacity of ≥58 W will have a total sinking capacity of 40 W, while a chassis with a slot cooling capacity of <58 W provides a total of 15 W.

When in operation, the PXIe-4147 should be kept in temperatures ranging from 0 °C to 55 °C. When not in use, it can be safely kept in a temperature range spanning from -40 °C to 71 °C. The device weighs 448 g (15.8 oz) with 20 W and 428 g (15.1 oz) with 40 W. It measures dimensions of 2.0 cm × 13.0 cm × 21.6 cm (0.8 in. × 5.1 in. × 8.5 in.).

Model NamePXIe-4147
Part Number786888-01
Part TypePXI Source Measure Unit
Available Sample Rates(1.8 MS/s)/N
Input Trigger TypesStart, Source, Sequence Advance, Measure
# Channels4
Operating Temp Range0 °C to 55 °C
Dimensions2.0 cm × 13.0 cm × 21.6 cm (0.8 in. × 5.1 in. × 8.5 in.)
Weight448 g (15.8 oz)- 20 W,  428 g (15.1 oz)- 40 W
WarrantyThree Year Warranty
ManufacturerNational Instruments

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn