PXIe-4147
Modular Systems > National Instruments > PXI Source Measure Units
Description: | PXIe-4147, 40 W, 4 Channel, PXI Source Measure Unit |
Need an Official Quote?
Or speak to a sales representative for additional information:
National Instruments PXIe-4147 Source Measure Unit
The PXIe-4147 (Part number: 786888-01) is a Source Measure Unit from National Instruments. Designed specifically for applications with high pin counts, the 4 channels of this device are each equipped with remote four-wire sensing capabilities, allowing for incredibly precise current and voltage readings. The features of the PXIe-4147 are made to improve flexibility and shorten test times- both important considerations when working with source and measurement applications. Boasting a nominal sample rate of (1.8 MS/s)/N, this device shortens the duration of measurements and offers a high resolution performance for projects of all sizes.
Switches, high-speed digital test modules, and other instruments can be easily synchronized to the PXIe-4147 by using a high-speed sequencing engine. NI’s SourceAdapt technology is another valuable addition to SMU toolkit. Built to use a digital control loop rather than an analog control loop, SourceAdapt optimizes the reaction of the PXIe-4147 to any load with minimal transients and maximum stability.
The sinking capacity of the PXIe-4147 is determined by the slot cooling capacity of the chassis. A chassis with a slot cooling capacity of ≥58 W will have a total sinking capacity of 40 W, while a chassis with a slot cooling capacity of <58 W provides a total of 15 W.
When in operation, the PXIe-4147 should be kept in temperatures ranging from 0 °C to 55 °C. When not in use, it can be safely kept in a temperature range spanning from -40 °C to 71 °C. The device weighs 448 g (15.8 oz) with 20 W and 428 g (15.1 oz) with 40 W. It measures dimensions of 2.0 cm × 13.0 cm × 21.6 cm (0.8 in. × 5.1 in. × 8.5 in.).
Model Name | PXIe-4147 |
---|---|
Part Number | 786888-01 |
Part Type | PXI Source Measure Unit |
Available Sample Rates | (1.8 MS/s)/N |
Input Trigger Types | Start, Source, Sequence Advance, Measure |
# Channels | 4 |
Operating Temp Range | 0 °C to 55 °C |
Dimensions | 2.0 cm × 13.0 cm × 21.6 cm (0.8 in. × 5.1 in. × 8.5 in.) |
Weight | 448 g (15.8 oz)- 20 W, 428 g (15.1 oz)- 40 W |
Warranty | Three Year Warranty |
Manufacturer | National Instruments |
PXIe-4147 PDF Manuals
PXIE 4147 ENVIRONMENTAL AND SAFETY INFORMATION.PDF
PXIE 4147 LETTER OF VOLATILITY.PDF
Why Buy From Apex Waves:
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
PXIe-4147
Modular Systems > National Instruments > PXI Source Measure Units
1-800-915-6216
- Description
- Technical Specifications
- Manuals & PDFs
National Instruments PXIe-4147 Source Measure Unit
The PXIe-4147 (Part number: 786888-01) is a Source Measure Unit from National Instruments. Designed specifically for applications with high pin counts, the 4 channels of this device are each equipped with remote four-wire sensing capabilities, allowing for incredibly precise current and voltage readings. The features of the PXIe-4147 are made to improve flexibility and shorten test times- both important considerations when working with source and measurement applications. Boasting a nominal sample rate of (1.8 MS/s)/N, this device shortens the duration of measurements and offers a high resolution performance for projects of all sizes.
Switches, high-speed digital test modules, and other instruments can be easily synchronized to the PXIe-4147 by using a high-speed sequencing engine. NI’s SourceAdapt technology is another valuable addition to SMU toolkit. Built to use a digital control loop rather than an analog control loop, SourceAdapt optimizes the reaction of the PXIe-4147 to any load with minimal transients and maximum stability.
The sinking capacity of the PXIe-4147 is determined by the slot cooling capacity of the chassis. A chassis with a slot cooling capacity of ≥58 W will have a total sinking capacity of 40 W, while a chassis with a slot cooling capacity of <58 W provides a total of 15 W.
When in operation, the PXIe-4147 should be kept in temperatures ranging from 0 °C to 55 °C. When not in use, it can be safely kept in a temperature range spanning from -40 °C to 71 °C. The device weighs 448 g (15.8 oz) with 20 W and 428 g (15.1 oz) with 40 W. It measures dimensions of 2.0 cm × 13.0 cm × 21.6 cm (0.8 in. × 5.1 in. × 8.5 in.).
Model Name | PXIe-4147 |
---|---|
Part Number | 786888-01 |
Part Type | PXI Source Measure Unit |
Available Sample Rates | (1.8 MS/s)/N |
Input Trigger Types | Start, Source, Sequence Advance, Measure |
# Channels | 4 |
Operating Temp Range | 0 °C to 55 °C |
Dimensions | 2.0 cm × 13.0 cm × 21.6 cm (0.8 in. × 5.1 in. × 8.5 in.) |
Weight | 448 g (15.8 oz)- 20 W, 428 g (15.1 oz)- 40 W |
Warranty | Three Year Warranty |
Manufacturer | National Instruments |
PXIe-4147 PDF Manuals & Diagrams
PXIe-4147 PDF Manuals
PXIE 4147 ENVIRONMENTAL AND SAFETY INFORMATION.PDF
PXIE 4147 LETTER OF VOLATILITY.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"