PCI-6011E, 16 Analog Input, 16-Bit, Multifunction DAQ
National Instruments PCI-6011E Multifunction DAQ
Featured with 16 single-ended or 8 differential Analog Inputs, two 12-bit Analog Outputs, and two 24-bit Counters, the National Instruments PCI-6011E (Part numbers: PCI-MIO-16XE-50, 777385-01) is a Multifunction Data Acquisition Device (DAQ) from the E Series. The analog inputs have a sampling rate of 20 kS/s and a 16-bit resolution, while the analog outputs have a 12-bit resolution with a sampling rate of 20 kS/s. For software-controlled routing of intraboard and interboard timing and digital signals, this module has eight programmable function input (PFI) lines. This Multifunction DAQ is a viable solution for applications ranging from control applications to high-speed data logging to high voltage sensor or signal measurements.
With this DAQ, users can achieve a seamless synchronization since it comes with an RTSI or PXI Trigger Bus to share control and timing signals between devices. For floating signal sources, this full-featured device offers RSE mode or single-ended mode in applications where higher than eight channels are required.
The National Instruments PCI-6011E incurs the least possible deviation (approx. 0.0006% of measured parameter per °C) as its circuitry is designed with special components to keep the effect of temperature changes at a minimum. Moreover, this model comes with entirely software controlled self-calibration. Precise voltage reference is also included for measurement and calibration accuracy. This Multifunction DAQ comes equipped with an NI PGIA, which is an instrument and measurement class amplifier that ensures settling times at all gains. The NI PCI-6011E is compatible with 5 VTTL digital triggers sourced from PFI <0...9>, RTSI <0...6> and generated at 10 ns (minimum) pulse width. There are two up/down counter/timers and one frequency scaler incorporated in this DAQ for Timing I/O related functions.
The PCI-6011E is run using the NIDAQmx driver software which is compatible with software packages/application development environments (ADEs) like LabVIEW, LabWindows/CVI, or Measurement Studio. The device hardware can be configured using the Measurement & Automation Explorer (MAX) tool. The NI device weighs 9.8 oz, and measures 6.9 x 4.2 in. in physical dimensions.
PCI-6011E Legacy Status has been announced by National Instruments, but will still be available for purchase and repairs by Apex Waves.
Model | PCI- 6011E |
---|---|
Manufacturer | National Instruments |
Part Numbers | 777385-01 and PCI-MIO-16XE-50 |
Type | Multifunction DAQ |
Channels | 16 Analog Inputs (16-Bit, 20 kS/s) or 8 differential 2 Analog Outputs (12 bits, 20 kS/s) 8 Digital Inputs/Outputs (50 kwords/s, 5 V/TTL Compatibility) 2 Counter/Timer I/O (24 bits) |
Power Requirements | +5 VDC - 1.1 A |
Dimensions | 6.9 in. × 4.2 in |
Weight | 9.8 oz. |
Driver Software | NI-DAQ 7 |
Warranty | Three Year Warranty |
PCI-6011E Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for PCI-6011E:
National Instruments PCI-6011E Frequently Asked Questions
Question: What is the overvoltage protection for the PCI-6011E?
Answer: The overvoltage protection for the PCI-6011E is ±15 V when powered off and ±25 V when powered on.
Question: Which DMA modes are available on the NI PCI-6011E?
Answer: The NI PCI-6011E has scatter-gather (demand transfer, single transfer) DMA modes available.
Question: When should the PCI-6011E be calibrated?
Answer: The PCI-6011E should be calibrated every year.
Question: What is the value of the power available at the I/O connector for the NI PCI-6011E?
Answer: The power available at the I/O connector for the NI PCI-6011E is +4.65 to +5.25 VDC at 1 A.
PCI-6011E PDF Manuals
ARCHIVED--PCI-E-SERIES-REGISTER-LEVEL-PROGRAMMER-MANUAL.PDF
DAQ-GETTING-STARTED-GUIDE-FOR-PCI-PCI-EXPRESS.PDF
DAQ-GETTING-STARTED-READ-ME-FIRST--NI-DAQMX-AND-DAQ-DEVICE-INSTALLATION-GUIDE.PDF
GUIDE-D_INITIATION-DAQ-POUR-PCI-PCI-EXPRESS.PDF
MULTIFUNCTION-IO-PRODUCT-FLYER.PDF
NI-60XX-60XXE-PINOUT-LABEL-FOR-THE-SCB-68.PDF
NI-60XX-60XXE-PINOUT-LABEL-FOR-THE-SCB-68A.PDF
NI-PCI-MIO-16XE-50--NI-6011E--SPECIFICATIONS.PDF
C3A0-LIRE-EN-PREMIER---GUIDE-DE28099INSTALLATION-DE-NI-DAQMX-ET-DES-PC3A9RIPHC3A9RIQUES-DAQ.PDF
Delivery:
Warranty:
All of our products are covered by our Apex Waves Warranty.
✓ 3 Year Warranty - New Surplus Parts
✓ 2 Year Warranty - Refurbished Parts
Returns:
No hassle return policy.
Dedicated customer service team.
Quick Quotes:
Receive Price & Availability Today!
Calibration:
Ask About Our Tiered Calibration Levels
Option & Modules:
Confirm Your Requirements or Versions
Repair:
Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Common Typos: