PXI-1050
Modular Systems > National Instruments > PXI Chassis
Description: | PXI-1050, 12-Slot, PXI Chassis |
Need an Official Quote?
Or speak to a sales representative for additional information:
National Instruments PXI-1050 PXI Chassis
Featured with 8 PXI Slots and 4 SCXI slots, the PXI-1050 (Part Numbers: 779199-01, 779199-02, 779199-03, and 779199-04) is a PXI Chassis manufactured by National Instruments. This PXI/SCXI Combination Chassis is an ideal solution for PXI measurement systems where additional signal conditioning, such as switching, isolation, filtering, and multiplexing is required. The PXI section of this chassis can accept a remote or an embedded controller and a variety of PXI modules like digital I/O or multifunction I/O. The remaining four SCXI slots can facilitate seamless integration of signal conditioning modules into a PXI based system. These modules offer isolation and other functions in addition to their primary analog and digital input conditioning functions. The SCXI slots also supply a low-noise environment for varying functions such as supplying power, signal conditioning for the SCXI modules. The NI PXI 1050 provides signal conditioning and high-accuracy measurements in a single chassis.
The PXI 1050 has diverse features such as a fuse, backplane fuses, a circuit breaker (which protect both the operator and the system in the event of a fault), fans and filters-which cool the device and minimizes contamination by dirt.
A variety of software packages and documentation can be used to set up the PXI-1050 chassis. They are: BridgeVIEW, ComponentWorks, LabVIEW for Windows, LabWindows/CVI for windows, Measure, NI-DAQ for PC compatibles, VirtualBench.
To obtain a high channel count arrangement, the user can always daisy-chain additional chassis to the NI PXI-1050 Chassis. Since the PXI-1050 is a powerful combination of plug-in devices, signal conditioning, and computer in one Chassis, it is ideal for applications with limited rack-mount space. This PXI Chassis has a unique structural design and is fully compatible with the PXI Specification (Rev. 2.1). Thus, the user can implement synchronization and advanced timing features as well. The PXI 1050 Chassis is designed to operate with 100, 120, 220, or 240 VAC line voltages, depending on the part number. Part number 779199-01 is 120 VAC, part number 779199-02 is 100 VAC, part number 779199-03 is 220 VAC, and part number 779199-04 is 240 VAC. The power entry mode features a dedicated voltage selection wheel that determines the voltage level for which the chassis is configured. For adequate module cooling, a cooling system comprised of two fans is incorporated, which works on forced air circulation technology.
PXI-1050 Obsolete Status has been announced by National Instruments, but the Chassis will still be available for purchase and repairs at Apex Waves.
Associated Part Numbers: 192213-01, 192213A-01, 192213B-01, 192213C-01, 192213C-31, 192213D-01, 779199-01, 779199-02, 779199-03, 779199-04
Model | PXI-1050 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 779199-01, 779199-02, 779199-03, 779199-04 |
HTS Code | 8473305100 |
Type | PXI Chassis |
Slots | 12 |
Slot Cooling Capacity | 25 W |
Power Supply Type | AC |
Dimensions | 16.2 by 17.3 by 7.0 in. |
Weight | 29 lb. |
Warranty | Three Year Warranty |
PXI-1050 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PXI-1050 Frequently Asked Questions
Question: What is the difference between each of the four part numbers for the NI PXI-1050 PXI/SCXI Combination Chassis?
Answer: Each of the four part numbers for the NI PXI-1050 PXI/SCXI Combination Chassis has a different input line voltage. First, part number 779199-01 is 120 VAC. Part number 779199-02 is 100 VAC. Part number 779199-03 is 220 VAC. Lastly, part number 779199-04 is 240 VAC.
Question: Is the PXI-8108 Embedded Controller compatible with the PXI 1050 Chassis?
Answer: Yes, the PXI-8108 Controller will work with the PXI 1050 Chassis.
Question: The LED light is not lighting up on my NI PXI-1050 Chassis. Is there another method to turn the power on for the SCXI slots, besides the switch on the front of the case?
Answer: If the LED light is not lit on the NI PXI-1050 Chassis, it is recommended to check the fuses and circuit breaker on the back of the chassis. If that does not appear to solve the issue, check that the power cable is functioning by testing it on a different machine. Lastly, ensure that the Chassis is plugged into the correct main voltage.
Question: Which types of applications is the NI PXI 1050 designed for?
Answer: The NI PXI 1050 works well for applications that necessitate extremely precise measurements and signal conditioning in one chassis.
PXI-1050 PDF Manuals
ARCHIVED NI PXI-1050 LETTER OF VOLATILITY.PDF
COMBUSTION ANALYSIS SYSTEM SOFTWARE USER MANUAL.PDF
GUIDE DE DC3A9MARRAGE SCXI DOCUMENT MULTILINGUE ANGLAIS FRANC3A7AIS ET ALLEMAND .PDF
NI PXI-1050 USER MANUAL AND SPECIFICATIONS.PDF
NI PXI SLOT BLOCKER INSTALLATION GUIDE.PDF
NI SWITCHES GETTING STARTED GUIDE FOR NI SCXI SWITCH MODULES.PDF
PXI EXPRESS CHASSIS PRODUCT FLYER.PDF
PXI PXI EXPRESS CHASSIS FAN FILTER KIT.PDF
PXI-1050 Diagrams
Driver Downloads for PXI-1050
OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit
Why Buy From Apex Waves:
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
PXI-1050
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
- Drivers
National Instruments PXI-1050 PXI Chassis
Featured with 8 PXI Slots and 4 SCXI slots, the PXI-1050 (Part Numbers: 779199-01, 779199-02, 779199-03, and 779199-04) is a PXI Chassis manufactured by National Instruments. This PXI/SCXI Combination Chassis is an ideal solution for PXI measurement systems where additional signal conditioning, such as switching, isolation, filtering, and multiplexing is required. The PXI section of this chassis can accept a remote or an embedded controller and a variety of PXI modules like digital I/O or multifunction I/O. The remaining four SCXI slots can facilitate seamless integration of signal conditioning modules into a PXI based system. These modules offer isolation and other functions in addition to their primary analog and digital input conditioning functions. The SCXI slots also supply a low-noise environment for varying functions such as supplying power, signal conditioning for the SCXI modules. The NI PXI 1050 provides signal conditioning and high-accuracy measurements in a single chassis.
The PXI 1050 has diverse features such as a fuse, backplane fuses, a circuit breaker (which protect both the operator and the system in the event of a fault), fans and filters-which cool the device and minimizes contamination by dirt.
A variety of software packages and documentation can be used to set up the PXI-1050 chassis. They are: BridgeVIEW, ComponentWorks, LabVIEW for Windows, LabWindows/CVI for windows, Measure, NI-DAQ for PC compatibles, VirtualBench.
To obtain a high channel count arrangement, the user can always daisy-chain additional chassis to the NI PXI-1050 Chassis. Since the PXI-1050 is a powerful combination of plug-in devices, signal conditioning, and computer in one Chassis, it is ideal for applications with limited rack-mount space. This PXI Chassis has a unique structural design and is fully compatible with the PXI Specification (Rev. 2.1). Thus, the user can implement synchronization and advanced timing features as well. The PXI 1050 Chassis is designed to operate with 100, 120, 220, or 240 VAC line voltages, depending on the part number. Part number 779199-01 is 120 VAC, part number 779199-02 is 100 VAC, part number 779199-03 is 220 VAC, and part number 779199-04 is 240 VAC. The power entry mode features a dedicated voltage selection wheel that determines the voltage level for which the chassis is configured. For adequate module cooling, a cooling system comprised of two fans is incorporated, which works on forced air circulation technology.
PXI-1050 Obsolete Status has been announced by National Instruments, but the Chassis will still be available for purchase and repairs at Apex Waves.
Model | PXI-1050 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 779199-01, 779199-02, 779199-03, 779199-04 |
HTS Code | 8473305100 |
Type | PXI Chassis |
Slots | 12 |
Slot Cooling Capacity | 25 W |
Power Supply Type | AC |
Dimensions | 16.2 by 17.3 by 7.0 in. |
Weight | 29 lb. |
Warranty | Three Year Warranty |
PXI-1050 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PXI-1050 Frequently Asked Questions
Question: What is the difference between each of the four part numbers for the NI PXI-1050 PXI/SCXI Combination Chassis?
Answer: Each of the four part numbers for the NI PXI-1050 PXI/SCXI Combination Chassis has a different input line voltage. First, part number 779199-01 is 120 VAC. Part number 779199-02 is 100 VAC. Part number 779199-03 is 220 VAC. Lastly, part number 779199-04 is 240 VAC.
Question: Is the PXI-8108 Embedded Controller compatible with the PXI 1050 Chassis?
Answer: Yes, the PXI-8108 Controller will work with the PXI 1050 Chassis.
Question: The LED light is not lighting up on my NI PXI-1050 Chassis. Is there another method to turn the power on for the SCXI slots, besides the switch on the front of the case?
Answer: If the LED light is not lit on the NI PXI-1050 Chassis, it is recommended to check the fuses and circuit breaker on the back of the chassis. If that does not appear to solve the issue, check that the power cable is functioning by testing it on a different machine. Lastly, ensure that the Chassis is plugged into the correct main voltage.
Question: Which types of applications is the NI PXI 1050 designed for?
Answer: The NI PXI 1050 works well for applications that necessitate extremely precise measurements and signal conditioning in one chassis.
PXI-1050 PDF Manuals & Diagrams
PXI-1050 PDF Manuals
ARCHIVED NI PXI-1050 LETTER OF VOLATILITY.PDF
COMBUSTION ANALYSIS SYSTEM SOFTWARE USER MANUAL.PDF
GUIDE DE DC3A9MARRAGE SCXI DOCUMENT MULTILINGUE ANGLAIS FRANC3A7AIS ET ALLEMAND .PDF
NI PXI-1050 USER MANUAL AND SPECIFICATIONS.PDF
NI PXI SLOT BLOCKER INSTALLATION GUIDE.PDF
NI SWITCHES GETTING STARTED GUIDE FOR NI SCXI SWITCH MODULES.PDF
PXI EXPRESS CHASSIS PRODUCT FLYER.PDF
PXI PXI EXPRESS CHASSIS FAN FILTER KIT.PDF
PXI-1050 Diagrams
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."